The correct method to start the experimental platform is just a few simple steps. Below is a detailed explanation for you.
1、 Find the power plug on the left console of the experimental platform and plug it into a 220V power socket to connect to the power supply.
2、 Next, close the cover of the leakage protection circuit breaker, which is located on the left side of the control screen.
3、 Rotate the emergency stop switch clockwise.
4、 Turn the auto coupling Pressure regulator to the lower position, and rotate it counterclockwise. Pay attention!
5、 The right console is now powered on and ready to use.
6、 Find the start button in the control, and you will hear the sound of the machine starting. When the power indicator light lights up, one of the input or voltage regulating indicator lights will also light up. The reading range of the Voltmeter on the power control panel is 220 V or called the voltage regulating value, which refers to the primary and secondary voltages of the autotransformer Pressure regulator. The correct startup steps of the experimental platform can ensure your improvement in work efficiency, and it is essential to operate and use the experimental platform in the correct and standardized way!